The curtain wall assembly occurs at an accent bar, stack joint, and column grid intersection. The accent bar aligns vertically with a ten-inch offset from column grid C and spans across the stack joint, which has a typical joint width of one and three-quarter inches. Structural silicone glazed four-sided joint edges and mullions beyond are positioned relative to the stack joint centerline and the centerline of the buckling-restrained brace below, with specific vertical dimensions of one foot six inches and fractional inch increments defining the component placement.
C F12 261' - 0" 1 / 2 " 1 9 / 3 2 " ACCENT BAR OF STACK JT 1 5 / 1 6 " 1 3 / 8 " 2 1 / 1 6 " MULLION BEYOND EDGE OF 4 SIDED SSG JT MULLION BEYOND OF BRB 1 ' - 6 " 2 1 / 2 " T Y P . 1 3 / 4 " 1 0 "