A structural steel beam connects to a wide flange column using a one-inch plate welded to the column flange. Five-sixteenths inch welds secure the plate with clips detailed to clear the column k-area. The beam and column sizes are sized per plan.
X 11 PL 1" x AS SHOWN WELD TO COLUMN PER 2/3.S-510, "w" = 5/16 SFRS CLIP SIM TO 2/3.S-510 TO CLEAR K-AREA 1' - 1 1/2" 1' - 1 1/2" 4" 4" BEAM PER PLAN BEAM PER PLAN COLUMN PER PLAN