A cold-formed steel stud wall terminates below a concrete mezzanine slab poured over metal decking. The assembly includes a two-inch metal stud track at the wall head with two-inch metal studs spaced below open-web joists and covered with gypsum board. A half-inch maximum gap between the top of the gypsum and studs and the bottom of the deck contains a UL-listed fire stop. Mineral wool insulation fills the void above the wall within the deck profile.
1/2" GAP MAX SECT A-A CONCRETE MEZZANINE SLAB METAL DECKING OPEN-WEB JOIST 2X METAL STUD TRACK STUD WALL GYP BOARD CONCRETE MEZZANINE SLAB METAL DECKING 2X METAL STUD TRACK STUD WALL GYP BOARD 2X METAL STUD MINERAL WOOL INSULATION U.L. LISTED FIRE STOP IN 1/2" GAP A & STUDS B.O. DECK T.O. GYP U.L. LISTED FIRE STOP IN 1/2" GAP 2X METAL STUD