Text on the drawing
DOOR CLEARANCES AT SWING DOORS - SECTION 404 FRONT APPROACH PULL SIDE 60" MIN 18" MIN 24" PREFERED FRONT APPROACH PUSH SIDE 48" MIN X X=0" TYP X=12" WHEN DOOR HAS CLOSER & LATCH Y 54" MIN X HINGE APPROACH PULL SIDE X=36" MIN WHEN Y=60" X=42" MIN WHEN 54"<Y<60" 42" MIN HINGE APPROACH PUSH SIDE 48" IF DOOR HAS LATCH & CLOSER 48" MIN 24" MIN LATCH APPROACH PULL SIDE 54" IF DOOR HAS CLOSER 42" MIN 24" MIN LATCH APPROACH PUSH SIDE 48" IF DOOR HAS CLOSER 22" MIN EXTENT OF CLEAR FLOOR SPACE, TYP NOTE: MANEUVERING CLEARANCE FOR A FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18" OF THE LATCH SIDE OF THE DOORWAY PROJECTS MORE THAN 8" BEYOND THE FACE OF THE DOOR. SEE SECTION 404.2.4.3 X X=0" TYP X=12" MIN IF DOOR HAS BOTH A CLOSER & LATCH