This stair section details the bottom landing condition bearing onto a concrete-filled metal deck floor slab. A one-inch cold joint separates the edge of slab and the stair infill concrete. The stair fabricator must account for lateral building movement in the connection design and coordinate adjacent steel dimensions prior to fabrication.
1" 2" GENERAL CONTRACTOR TO COORDINATE STAIR FABRICATOR'S REVIEW AND APPROVAL OF ADJACENT BUILDING STEEL DIMENSIONS AND DETAILS PRIOR TO STEEL FABRICATION. CONCRETE ON MTL DECK STAIR FABRICATOR TO ACCOUNT FOR LATERAL MOVEMENT OF BUILDING IN STAIR CONNECTION DESIGN. EOS 1" COLD JOINT BETWEEN CONCRETE EOS AND STAIR INFILL. FOR ADDITIONAL INFO SEE DETAIL / 4 A-610